Coating type Wavelength, nm Pulse duration, ps Repetition rate, Hz Beam diameter, mm Fluence, J/cm2    
HR 1064 370 20 2.4 2.58    
HR 532 350 20 2.1 1.64    
HR 1030 10 1000 0.154 8.313 Product example  
AR 1064 370 20 2.3 5.5    
AR 532 350 20 2.1 2.1    
AR 343 1 1000 1 0.39 Report  
Polarizer 1030 10 10000 0.115 2.7 Report  

Disclaimer

Values are the result of LIDT test procedure according to ISO standards or based on the measurements done at customer sites. While the values are trustworthy, it doesn’t mean that they can be transferred to final product specifications as the safety factor should be considered.