LIDT measurements and reports

Coating type Wavelength, nm Pulse duration, fs Repetition rate, kHz Beam diameter, μm Fluence, J/cm2    
HR 1030 500.9 10 185 0.78 Report  
HR 1030 507 1 136.5 1.183 Report  
HR 343 180 10 30 0.286 Report Product example
HR 343 300.8 200 40.9 0.376 Report  
HR 258 305.4 200 34.4 0.306 Report  
AR 515 191.4 300 58.7 0.052 Report  
Polarizer 1030 500 10 175 0.77 Report  

 

Disclaimer